Предыдущая | Следующая |
D first | State: up | Device | /dev/ad0s1e | Avail: 0/21248 MB (0%) |
D second | State: up | Device | /dev/ad2s1e | Avail: 0/21248 MB (0%) |
V var | State: up | Plexes: | 2 Size: | 512 MB |
V tmp | State: up | Plexes: | 2 Size: | 256 MB |
V local | State: up | Plexes: | 2 Size: | 20 GB |
P var.p0 | C State: up | Subdisks: | 1 Size: | 512 MB |
P var.p1 | C State: faulty | Subdisks: | 1 Size: | 512 MB |
P tmp.p0 | C State: up | Subdisks: | 1 Size: | 256 MB |
P tmp.p1 | C State: faulty | Subdisks: | 1 Size: | 256 MB |
P local.p0 | C State: up | Subdisks: | 1 Size: | 20 GB |
P local.p1 | C State: faulty | Subdisks: | 1 Size: | 20 GB |
S var.p0.s0 | State: up | PO: | 0 B Size: | 512 MB |
S var.p1.s0 | State: empty | PO: | 0 B Size: | 512 MB |
S tmp.p0.s0 | State: up | PO: | 0 B Size: | 256 MB |
S tmp.p1.s0 | State: empty | PO: | 0 B Size: | 256 MB |
S local.p0.s0 | State: up | PO: | 0 B Size: | 20 GB |
S local.p1.s0 | State: empty | PO: | 0 B Size: | 20 GB |
D first | State: up | Device | /dev/ad0s1e | Avail: 0/21248 MB (0%) |
D second | State: up | Device | /dev/ad2s1e | Avail: 0/21248 MB (0%) |
V var | State: up | Plexes: | 2 Size: | 512 MB |
V tmp | State: up | Plexes: | 2 Size: | 256 MB |
V local | State: up | Plexes: | 2 Size: | 20 GB |
P var.p0 | C State: up | Subdisks: | 1 Size: | 512 MB |
P var.p1 | C State: up | Subdisks: | 1 Size: | 512 MB |
P tmp.p0 | C State: up | Subdisks: | 1 Size: | 256 MB |
P tmp.p1 | C State: faulty | Subdisks: | 1 Size: | 256 MB |
P local.p0 | C State: up | Subdisks: | 1 Size: | 20 GB |
P local.p1 | C State: faulty | Subdisks: | 1 Size: | 20 GB |
S var.p0.s0 | State: up | PO: | 0 B Size: | 512 MB |
S var.p1.s0 | State: up | PO: | 0 B Size: | 512 MB |
S tmp.p0.s0 | State: up | PO: | 0 B Size: | 256 MB |
S tmp.p1.s0 | State: empty | PO: | 0 B Size: | 256 MB |
S local.p0.s0 | State: up | PO: | 0 B Size: | 20 GB |
S local.p1.s0 | State: empty | PO: | 0 B Size: | 20 GB |
D first | State: up | Device | /dev/ad0s1e | Avail: 0/21248 MB (0%) |
D second | State: up | Device | /dev/ad2s1e | Avail: 0/21248 MB (0%) |
V var | State: up | Plexes: | 2 Size: | 512 MB |
V tmp | State: up | Plexes: | 2 Size: | 256 MB |
V local | State: up | Plexes: | 2 Size: | 20 GB |
P var.p0 | C State: up | Subdisks: | 1 Size: | 512 MB |
P var.p1 | C State: up | Subdisks: | 1 Size: | 512 MB |
P tmp.p0 | C State: up | Subdisks: | 1 Size: | 256 MB |
P tmp.p1 | C State: up | Subdisks: | 1 Size: | 256 MB |
P local.p0 | C State: up | Subdisks: | 1 Size: | 20 GB |
P local.p1 | C State: up | Subdisks: | 1 Size: | 20 GB |
S var.p0.s0 | State: up | PO: | 0 B Size: | 512 MB |
S var.p1.s0 | State: up | PO: | 0 B Size: | 512 MB |
S tmp.p0.s0 | State: up | PO: | 0 B Size: | 256 MB |
S local.p0.s0 | State: up | PO: | 0 B Size: | 20 GB |
S tmp.p1.s0 | State: up | PO: | 0 B Size: | 256 MB |
S local.p0.s0 | State: up | PO: | 0 B Size: | 20 GB |
S local.p1.s0 | State: up | PO: | 0 B Size: | 20 GB |
Filesystem | Size | Used | Avail | Capacity | Mounted on |
/dev/acd0a | 339M | 339M | 0B | 100% | / |
mfs:10 | 5.9M | 16K | 5.4M | 0% | /dev |
/dev/vinum/var | 528M | 14M | 472M | 3% | /var |
/dev/vinum/tmp | 264M | 2.0K | 243M | 0% | /tmp |
/dev/vinum/local | 21G | 160M | 19G | 1% | /usr/local |
procfs | 4.1K | 4.1K | 0B | 100% | /proc |
Id Refs Address Size Name 1 11 0xc0100000 394090 kernel 2 1 0xc1022000 c3000 vinum.ko
Для повышения надежности и отказоустойчивости вашего сервера, вы можете добавить возможность загрузки его с жестких дисков. Как это сделать, описано в разделе Добавим немного гибкости.
Предыдущая | Содержание | Следующая |
Запуск программной RAID-1 системы | Запуск RAID-1 под управлением ccd |